Call 0804895499894% Response Rate
Send E-mail

Transformer Testing

Providing you the best range of kingsine ct/pt analyzer with effective & timely delivery.
Get CALLBACK

Kingsine CT/PT Analyzer

Kingsine CT/PT Analyzer
 
Get Best Quote
Approx. Rs 18 Lakh / Piece
Get Latest Price
Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Machine TypeCT/PT Analyzer
Model Name/NumberKingsine KT210
Usage/ApplicationPower Testing
ParametersMany Parameters can be tested like Winding Resistance, Saturated inductance, Unsaturated Inductance
Frequency50/60Hz
Dimension360 x 140 x 325mm
Data InterfaceYes available
Weight8kg
Power Requirements176 Vac to 264 Vac @ 10A Max

·       Adopt 9.7 inch touch screen TFT LCD display with clear and beautiful software interface design, user can operate easily.

·       AC/DC current input for wide range only, satisfy all power supply standard requested.

·       Easy to operate, measure quickly, all test can be done automatically based on the same connection line type except overload impedance measurement.

·       Adopt low voltage & variable frequency measurement method, it can test knee point voltage up to 30kV transformer as output max voltage only is 120V and max peak value current is 15A, high security.

·       Portable design with light weight of 8kg, suitable for field test of electric power system, manufacturing factory of current transformer or laboratory to use.

·       High measurement accuracy, resistance accuracy is 0.1%+1mΩ, phase accuracy±0.05 degree, variable accuracy is ±0.1% (1-5000 ), variable accuracy is ±0.2%(5000-10000).

·       It can test current transformer according to IEC60044-1, IEC60044-6, IEC61869-2 and ANSI30/45 standard etc.

·       Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient characteristic, ratio difference, angle difference and polarity. It can also test exact limit coefficient(ALF), device security coefficient(FS), secondary time constant(Ts), remanence coefficient(Kr), transient area coefficient(Ktd), inflexion voltage, current, level, saturation inductance, un-saturation inductance, 5% 10% error curve, of current transformer, hysteresis loop for current transformer, and evaluate test result according to defined standard.

·       PT Test As for those inductive PT based on the definition of GB1207-2006(IEC60044-2), KT210 CT/PT Analyzer can also test them. KT210 CT/PT Analyzer can do variable ratio, polarity and secondary winding excitation test of inductive PT.


Yes! I am Interested
Explore More Products
X
Find UsAmit Verma (Director) Edvantest Measure Technologies Private Limited
upper Ground Floor H-30 Street No-03 H-block ,shakarpur, Bhagirath Palace, Shakarpur Khas, New Delhi - 110092, Delhi, India
SEND SMS
SEND E-MAIL
Share Us: